89
Latest score
50%
Pass rate
4
Inspections
3
Critical violations

Location

Latest inspection

RESULT UNAVAILABLE
May 14, 2026FOLLOW-UP INSPECTION93 days ago

Other site visit for facility that had a small fire at the cook line over the weekend and fire suppression system was set off. The ventilation hood system was out of service due to power issues at time of last inspection on 5/12/26. Hood was verified and to be operating. Per PIC, all affected areas by the fire has been cleaned and sanitized. All contaminated food has been discarded. Facility is cleared to resume regular operations.

Inspection Timeline

May 14, 2026Latest
Unknown
FOLLOW-UP INSPECTION
May 12, 2026
PassedScore: 89/100
ROUTINE INSPECTION
89
Jun 17, 2025
Passed
FOLLOW-UP INSPECTION
Jun 16, 2025
ConditionalScore: 76/100
ROUTINE INSPECTION
76

Violations Analysis

3
Critical Violations
1 in last 3 inspections
5
Non-Critical
8
Total Violations
Across 4 inspections

Complete inspection history

4 inspections
UnknownLatest May 14, 2026
N/A

FOLLOW-UP INSPECTION

Other site visit for facility that had a small fire at the cook line over the weekend and fire suppression system was set off. The ventilation hood system was out of service due to power issues at time of last inspection on 5/12/26. Hood was verified and to be operating. Per PIC, all affected areas by the fire has been cleaned and sanitized. All contaminated food has been discarded. Facility is cleared to resume regular operations.

No reported violations
Pass May 12, 2026
89/100

ROUTINE INSPECTION

Note: Routine inspection conducted in conjunction with a service request for a kitchen fire. Contact this department for a follow-up inspection when ansul testing has been completed and hood is fully functional.

2 reported violations
  • K07: Proper hot and cold holding temperaturesCritical

    Measured chicpeas at 63 F, kidney beans at 54 F, potato salad at 48 F and diced tomatoes at 53 F at the salad bar. PIC stated that the food was removed from the walk in/ preparation at 11am. [CA] PHFs shall be held at 41°F or below or at 135°F or above. [COS] PHF's at the salad bar are to be discarded following the lunch service at 1:30pm. Recommend utilizing TPHC for all PHF's at the salad bar.

  • K06: Adequate handwash facilities supplied, accessible

    Lack of soap at the hand wash sink adjacent to the warewashing area. [CA] Provide handwashing cleanser in dispenser at handwash stations at all times. [COS] Soap dispenser refilled.

Pass Jun 17, 2025
N/A

FOLLOW-UP INSPECTION

Follow-up for routine inspection conducted on 6/16/25. Verified that major violations are still in compliance: - Potentially hazardous foods are held and measured at proper holding temperatures. See measured observations. - Employee was able to demonstrate proper manual warewashing.

No reported violations
Conditional Pass Jun 16, 2025
76/100

ROUTINE INSPECTION

Facility has a "general store" across from the front counter. All items in the store are prepackaged and managed by the kitchen.

6 reported violations
  • K14: Food contact surfaces clean, sanitizedCritical

    Employee observed manually washing a pot without the sanitizing step. The pot was washed with soap, rinsed with water, and then placed back under the table by the cook line. [CA] Manual warewashing shall be accomplished by using a three-compartment sink where the utensils are first precleaned, washed with hot soapy water, rinsed with hot water, sanitized with an approved method, and air dried. Use 1 TBS of bleach (5.25%) per 1 gal. of water for chlorine solution (100 PPM). Use 1 tbs of quaternary ammonium (10%) per 2 gal. of water for quaternary ammonium (200 PPM). [COS] Employee took the pot back to the three compartment sink where it was placed in sanitizer solution.

  • K26: Approved thawing methods used; frozen food

    Frozen chicken observed thawing on rack inside the dry storage room. [CA] Frozen potentially hazardous food shall only be thawed in one of the following ways: 1) under refrigeration that maintains the food temperature at 41°F or below, 2) completely submerged under potable running water for a period not to exceed two hours at a water temperature of 70°F or below, and with sufficient water velocity to agitate and flush off loose particles into the sink drain, 3) in a microwave oven if immediately followed by immediate preparation, 4) as part of a cooking process.

  • K35: Equipment, utensils: Approved, in good repair, adequate capacity

    At time of inspection, facility's walk-in cooler was removed and in the process of being replaced. Facility had purchased and are using unapproved household refrigerators stored outside of the kitchen. [CA] A food facility shall only used approved equipment within areas approved for food storage The addition or replacement of food equipment are required to be submitted to this department's Plan Check for review and approval prior to installation. Plan Check submittal is required for the replacement of the walk-in cooler. Additional information for Plan Check requirements can be located online at www.Ehinfo.org .

  • K07: Proper hot and cold holding temperaturesCritical

    Raw shell eggs are stored inside the dry storage room and measured at 57F. Per employee, the eggs were placed inside within the hour. [CA] Potentially hazardous foods when cold holding shall be held at or below 41F. [COS] Employee relocated the eggs into a reach-in cooler.

  • K27: Food separated and protected

    Container of raw salmon is observed stored on top of ready-to-eat foods inside the upright reach-in cooler located by the door into the dining area. [CA] Store raw foods separate or below ready-to-eat foods to prevent cross-contamination.

  • K38: Adequate ventilation/lighting; designated areas, use

    Ventilation hood does not appear able to capture all the smoke that is generated from use of the grill. Smoke was building up in the the kitchen area. [CA] Provide approved exhaust hood ventilation over all cooking equipment as required to effectively remove cooking odors, smoke, steam, grease, heat, and vapors. Ensure that cooking equipment is within the minimum 6 inch overhang of the ventilation hood.

Source: Santa Clara County open data. Records are supplied as-is and may take 24–48 hours to reflect a newly published inspection.