ROUTINE INSPECTION
7 reported violations
- K41: Plumbing approved, installed, in good repair; proper backflow devices
Observed a flexible tubing connected to the ice machine and the end of the tubing is placed into the floor sink. [Corrective Action] Discontinue flexible tubing and replace with a durable tube such as a PVC pipe. The end of the pipe shall drain into the floor sink with an air gap of at least 1 inch above the rim of the floor sink.
- K33: Nonfood contact surfaces clean
Heavy dust accumulation on the fan guard in the single door upright display cooler. [Corrective Action] Maintain clean.
- K35: Equipment, utensils: Approved, in good repair, adequate capacity
Broken door handle on the single door upright cooler (Elite brand). [Corrective Action] Repair or replace the door hande.
- K38: Adequate ventilation/lighting; designated areas, use
The kitchen and back area was hot. [Corrective Action] Provide adequate ventilation.
- K29: Toxic substances properly identified, stored, used
Quaternary ammonium sanitizer at the 3 compartment sink was measured at 400 ppm. [Corrective Action] Maintain quaternary sanitizer at 200 ppm.
- K45: Floor, walls, ceilings: built,maintained, clean
Observed paint peeling from the ceiling above the the water heater. [Corrective Action] Maintain ceiling in good condition.
- K14: Food contact surfaces clean, sanitized
Observed grime accumulation inside the ice machine near the ice chute. [Corrective Action] Thoroughly clean and sanitize.