- K38: Adequate ventilation/lighting; designated areas, use
Facility has a flat grill and electric burner outside the exhaust hood. Per PIC, the burner is used to cook eggs and the flat grill to toast bread, cook pancakes, and other brunch items.
[CA] Provide approved exhaust hood ventilation over all cooking equipment as required to effectively remove cooking odors, smoke, steam, grease, heat, and vapors.
- K34: Warewash facilities: installed/maintained; test strips
Facility lacks testing materials for their choice of sanitizer at the bar service counter, ethyl alcohol (Purell).
[CA] Testing equipment and materials shall be provided to adequately measure the applicable sanitization method used during manual or mechanical warewashing.
- K40: Wiping cloths: properly used, stored
1. A wiping cloth was stored in a solution of sanitizer (Purell) that was unable to be measured by the facility.
2. Several wiping cloths were found stored on prep surfaces.
[CA] Wiping towels shall be stored in sanitizing solution of an approved concentration when not in use (100 ppm - chlorine, 200 ppm - quaternary ammonium).
- K47: Signs posted; last inspection report available
1. The Environmental Health permit was not posted in public view.
[CA] The health permit issued by this department shall be posted in a conspicuous place in the food facility.
2. The restroom lacks a handwash reminder sign.
[CA] A sign or poster that notifies food employees to wash their hands shall be posted at all handwashing stations used by food employees.
- K01: Demonstration of knowledge; food safety certification
Facility lacks a food safety certificate upon request.
[CA] Food facilities that prepare, handle, or serve non-prepackaged potentially hazard foods shall have a valid Food Safety Certificate available for review at all times.
- K07: Proper hot and cold holding temperaturesCritical
PHFs were found stored out of temperature control on the prep sink drainboard. Eggs, bean sprouts, fried tofu measured between 50-60F. Per PIC, they were left out for about an hour.
[CA] PHFs shall be held at 41°F or below or at 135°F or above.
[COS]] Items were moved into the upright cooler to cool back down.
- K26: Approved thawing methods used; frozen food
Facility was found thawing shrimp and chicken in the handwash sink basin in the kitchen.
[CA] Frozen potentially hazardous food shall only be thawed in one of the following ways: 1) under refrigeration that maintains the food temperature at 41°F or below, 2) completely submerged under potable running water for a period not to exceed two hours at a water temperature of 70°F or below, and with sufficient water velocity to agitate and flush off loose particles into the sink drain, 3) in a microwave oven if immediately followed by immediate preparation, 4) as part of a cooking process.
[COS] Items were moved to the upright cooler.
- K36: Equipment, utensils, linens: Proper storage and use
Water for rice spoon was measured at 79F.
[CA] Utensils shall be stored in the following manner: 1) in the food with their handles above the top of the food and the container, 2) in running water, 3) in a container of water at 135°F or above, 4) at room temperature if washed within 4 hours of initial use.
- K06: Adequate handwash facilities supplied, accessibleCritical
No soap was available to wash hands.
Note: Facility removed the handwash sink at the bar area. Per PIC, they use the prep sink in the bar service area. See K41 for more information.
[CA] All food facilities shall provide an operable handwashing station.
[SA] Facility provided hand soap at the prep sink.
note: There is another prep sink in the kitchen area and another handwash sink, however, the faciltiy has blocked easy access to the handwash station from the bar service area with placement of prep table.
- K44: Premises clean, in good repair; Personal/chemical storage; Adequate vermin-proofing
The back door was left open. (Wooden and screen doors).
[CA] Keep back door closed at all times to prevent the entrance and harborage of vermin.
- K18: Compliance with variance/ROP/HACCP PlanCritical
Facility was observed having reduced oxygen packaged foods. Per PIC, they packaged them yesterday and are packaged to be sous vide. Items lacked any labeling or dates. Chicken was found in an upright cooler and beef was found in an upright non-ANSI freezer.
[CA] The food facility shall obtain a HACCP plan approval prior to packaging PHFs using a reduced-oxygen packaging method. Submit plans to this department for addition of a vacuum chamber machine. Plan check submittal must contain an approved HACCP plan from the California Department of Public Health or Standard Operating Procedures that comply with exemption requirements stated in section 114419. (B)(2) of the California Retail Food Code.
[COS] Items were VC&D.
- K35: Equipment, utensils: Approved, in good repair, adequate capacity
1. Facility has a non-ANSI flat grill placed on a prep table near the dry storage room.
2. Facility has a non-ANSI waffle maker placed on a prep table near the dry storage room.
3. Facility has a non-ANSI chest freezer.
4. Facility has a non-ANSI upright freezer.
[CA] New and/or replacement food equipment shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program (e.g. NSF, UL EPH, UL Sanitation, CSA Sanitation, or ETL Sanitation).
- K41: Plumbing approved, installed, in good repair; proper backflow devices
Facility has removed the handwash sink in the front of house area by the bar service.
[CA] All plumbing and plumbing fixtures shall be installed in compliance with applicable local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Reinstall the handwash sink and maintain in good repair and stocked.