FOLLOW-UP INSPECTION
Follow-up inspection for conditional pass due to improper holding temperatures and improper cooling. The following violations were corrected: K07M - Improper holding temperatures - Observed walk-in refrigerator was being repaired during time of inspection. Per operator, walk-in refrigerator is undergoing installation of replacement condenser unit. - Observed potentially hazardous foods stored in a refrigerated truck outside while installation is occurring. Measured ambient air temperature of refrigerated truck at 39F. - Operator to provide update of installation and completion to district inspector. - Measured potentially hazardous foods in 2 door reach in refrigerator at 36F. K08M - Improper cooling - No improper cooling occurred during time of inspection. K23 - Vermin - Observed all areas with previous noted rodent droppings have been cleaned and sanitized. - No new evidence of activity observed. The following violations have not been corrected: K35 - Equipment maintained in good repair - Walk-in refrigerator undergoing installation of new unit and has not been confirmed to be properly functioning and able to maintain potentially hazardous foods at 41F and below. K38 - Ventilation - Measured ambient air temperature of the facility at 86F. - Operator stated plan in place to install AC for the kitchen area.