ROUTINE INSPECTION
3 reported violations
- K35: Equipment, utensils: Approved, in good repair, adequate capacity
Facility is lacking chlorine sanitizer test strips. [CA] Test strips shall be provided to adequately measure the chlorine sanitizer concentration used during mechanical warewashing.
- K21: Hot and cold water available
*Repeat violation: Water temperature at the 3 composition sink, preparation sink, and janitorial sink measured between 105-108F. [CA] Hot water shall be supplied at a minimum temperature of at least 120°F measured from the faucet throughout facility except at handwash sinks.
- K41: Plumbing approved, installed, in good repair; proper backflow devices
Observed pipes extending into floor sinks below the preparation sink and below the espresso machine. [CA] All equipment that discharges liquid waste shall be drained by means of indirect waste pipes, and all wastes drained by them shall discharge through an air gap into a floor sink or other approved type of receptor. Air gaps must be at least twice the diameter of the inlet and no less than 1 inch.